ZDBC240NBS – GE Monogram Stainless Steel Beverage Center
Dimensions and Specifications (in inches)
Installation Space
Side-by-Side Installation
For a complete refreshment center, install a Monogram Wine Reserve
and Beverage Center together.
The Monogram® Beverage Center may be installed beneath a
countertop or can be used free-standing.
• If installing between frameless cabinets, a 1/2"-wide filler strip
or side panel may be required. The filler strip will act as a spacer
between the door case and adjacent cabinet and will prevent
interference with cabinet door swing. The width of the opening
must include filler panels.
• Products must operate from separate properly grounded
receptacles.
Door Swing Clearances
All Monogram Refrigeration Modules are factory set for a 110°
door swing.
Note: When installed, the door should project forward 1" of
adjacent 24"-deep cabinets.
When installed in a corner:
• Allow the minimum door swing clearances shown.
• The minimum clearance shown at 90° will allow full extension
of drawers and shelves.
Locate Outlet
10-1/2"
10"
Minimum to Wall
23-3/4"
24" Min.
9"
Max.
34-1/2"-35"
90° Door
Swing
110° Door
Swing
21-5/8"
1-1/2"
23-3/4" Min.
34-1/4"
to
34-3/4"
23-5/8"
110°
90°
25-1/2"
Including
Handle
23-3/4"
4"
Minimum to Wall
Electrical
Location Requirements
A 120V, 60Hz, 15 or 20 amp power supply is required. An individual
properly grounded branch circuit or circuit breaker is recommended.
Install a properly grounded 3-prong electrical recessed into the
back wall as shown. Electrical must be located on rear wall as shown.
All Monogram Refrigeration Modules may be closed in on the top
and sides as long as the front is unobstructed for air circulation and
door swing.
• Do not install these products where the temperatures will go
below 55°F (13°C) or above 90°F (32°C).
Note: GFCI (ground fault circuit interrupter) is not recommended.
• Do not install where they will be subject to direct sunlight,
heat or moisture.
• These products are not designed to be stacked one over the other.
Listed by
Underwriters
Laboratories
®
For answers to your Monogram, GE Profile™ or
GE® appliance questions, visit our website at
GEAppliances.com or call GE Answer Center®
service, 800.626.2000.
Specification Revised 4/06
120022
|
Dyson Vacuum Cleaner DCO3 User Manual
Electro Voice Music Mixer PSX600 User Manual
Estate Refrigerator TS22CFXT User Manual
Euro Pro Carpet Cleaner S3601CO User Manual
Exmark Lawn Mower M216KA M216KASP User Manual
Extron electronic Projector Accessories 70 526 03 User Manual
Festool Sander RS 400 EQ User Manual
Garmin GPS Receiver 12 User Manual
GE Air Conditioner AEE12DK User Manual
GE Indoor Furnishings SHOWBIZ User Manual